Order No. | Name | Model | D65 | TL84 | F | UV | CWF | TL83 | Voltage |
10118 | Standard light source booth | P120 six light source(220V) | 2pcs | 2pcs | 6pcs | 1pcs | 2pcs | 2pcs | 220V/50Hz |
10818 | Standard light source booth | P120 six light source(115V) | 2pcs | 2pcs | 6pcs | 1pcs | 2pcs | 2pcs | 115V/60Hz |
Light Source | Color viewing booths application | Color temperature(k) | Power(W) |
D65 | International standard Artificial Daylight | 6500 | 36 |
TL84 | Applied to stores in Europe, Japan and China | 4000 | 36 |
CWF | (Cool White Fluorescent) American Standard | 4150 | 36 |
F/A | "Sun-setting Light Yellow" incandescent light source (imitation of sunset) | 2700 | 40 |
UV | Viewing under ultraviolet light to detect and evaluate optical brighteners or fluorescent pigments | Wave length:365nm | 36 |
TL83 | Warm White Fluorescent American Standard | 3000 | 36 |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Light Booth
The repeatability is an important parameter for the accuracy of the colorimeter. Threenh Technology portable colorimeter for color measurements tandard deviation ΔE*ab is within 0.03 (Measurement condition: the average value of 30 measurements on the white board at an interval of 3s after calibration). Each colorimeter can pass the qualified inspection before leaving the factory to ensure it conforms to the standard of China Metrology Institute.
a. When the colorimeter is disconnected to the PC, "Connection Timeout" will occur. At the moment, you have to check whether the USB cable is well connected the colorimeter and the PC. Then you can re-plug the USB to try out.
b. After ensuring the colorimeter is connected to the PC with USB cable, turn on the colorimeter and enter the main menu. Select "Comm" and press "Enter" key to start communication.
c. Turn off CQCS3 software, and reopen it.
After receiving NH310/NH300, you have to perform white and black calibration manually when first starting.
a. Connect colorimeter to the PC with USB cable.
b. Turn on the colorimeter to enter main menu. Select "Comm" and press "Enter" key to start communication.
c. Right click on "My Computer" on the desktop. Click "Manage" -> "Device Manager" -> "Ports", you can see similar display as "SCI USB2Serial (COM6)".
d. Click "Settings->Communication Parameters" in CQCS3 software interface. Select the corresponding port in "Serial Port".
Yes, we offer free samples for test, you are welcome to order samples to experience our excellent quality and service.