3nh YH1210 Haze Meter can easily realize ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, haze test. Open sample chamber can be vertical, horizontal test, adapt to more samples under test. YH1210 haze meter adopts PD array detector, which can meet the visual response of CIE V(λ)2 degrees. The compensation method can realize the high-precision and repeatable measurement of transmittance and haze data.
Advantages of YH1210 Haze Meter
1.Double standard ISO & ASTM
It can meet the test standard requirements of different users; meet the standards: ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136
2.Easy operation and faster and more accurate measurement
The YH1210 Haze Meter is equipped with large size touch screen, easy to operate, using PD array detector, to meet the CIE V(λ)2 degree visual response to achieve high precision and repeatable transmittance and haze measurement. USB data output device, can be connected with the laboratory system.
3.Dynamic measurement
Independent light source detector and temperature sensor to monitor the light source and environmental changes at all times to ensure reliable test data.
4.Compensation port to make the measurement data more accurate
Meet the standard of ASTM D1003 non-compensation method, ISO 13468 compensation method, it can do full light transmittance, haze test, and provide more accurate test results.
5.Convenient measurement and wide sample adaptation
Open measurement area for vertical and horizontal testing to accommodate more samples under test.
6.Quality management software
It provides powerful software for measuring and analyzing haze, color and light transmittance, which is suitable for quality monitoring and tabulating management of haze, light transmittance and color data in various industries. Data the management of users on the PC computer, compare the haze, transmittance and color differences, generate test report forms, facilitate customer customization and management.
Application of YH1210 Haze Meter
YH1210 Haze Meter is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects.
Technical Specification
Product model | YH1210 Haze Meter |
Geometry | Transmittance: 0/D (parallel illumination, diffuse receiving) in accordance with standards: ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 |
Characteristic | The instrument can easily realize ASTM D1003 uncompensated method, ISO 13468 compensation method, Full transmittance, haze test. Open measurement area for vertical and horizontal testing. It is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects. |
Integrating sphere size | Φ 154 mm |
Light source | 400 ~ 700 nm combined LED light source |
Spectrophotometric Mode | / |
Sensor | PD array detector, satisfying CIE V(λ)2 degree visual response |
Wavelength range | / |
Wavelength interval | / |
Half bandwidth | / |
Measurement Range | 0-100% |
Measuring aperture | Φ20 mm/Φ15 mm/Φ8 mm/Φ4 mm (select single aperture) |
Sample size | Thickness less than 105 mm |
Color space | / |
Chromatic formula | / |
Other chromaticity index | Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM), |
Observer angle | 2 ° |
Light source | D65,A,C |
Display Data | Pass/fail result |
Measurement time | About 1.5s |
Resolution | 0.01 unit |
Repeatability | Φ20 mm aperture, less than 0.1 (after instrument preheating and correction, test the standard nebulizer with the nebulization of about 40 at an interval of 5s for 30 times of standard deviation) |
Inter-instrument Error | Φ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5s) |
Dimensions | Length X Width X Height = 487X260X298mm |
Weight | Approx. 8.0 kg |
Power supply | 24V 3A , DCpower adapter |
Illuminant Life Span | > 3 million measurements in 5 years |
Display | TFT True Color 7 inch, Capacitive Touchscreen |
Interface | USB, Print Serial |
Data Storage | 1,000 samples, 20,000 samples |
Language | Simplified Chinese, Traditional Chinese, English |
Operating Temperature | 0 to 40 ° C (32 to 104 ° F) |
Storage Temperature | - 20 – 50 ° C (-4 – 122 ° F) |
Standard Accessories | Power adapter, user manual, quality management software (download), USB cable, 0% calibration box, measuring aperture |
Optional Accessories | Micro printer, Test Fixture, Standard haze sheet, Footswitch |
Notes: | Subject to change without notice |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Haze Meters
The repeatability is an important parameter for the accuracy of the colorimeter. Threenh Technology portable colorimeter for color measurements tandard deviation ΔE*ab is within 0.03 (Measurement condition: the average value of 30 measurements on the white board at an interval of 3s after calibration). Each colorimeter can pass the qualified inspection before leaving the factory to ensure it conforms to the standard of China Metrology Institute.
a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.
b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.
c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.
d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.
e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.
To answer this question, you first need to clarify your specific needs:
Is it for simple color quality control (QC)?
To coordinate with supply chain color management?
To monitor on-line color stability?
Do you require computer color matching or production color correction?
What is your budget?
Systematic supervision and evaluation of color performance in dyed products?
If you aren’t fully clear about your requirements at the initial stage, our color management engineers are ready to communicate with you. We will recommend solutions tailored to your needs. When conditions permit, we can provide prototype demonstrations and trial testing to ensure the instrument meets your practical application requirements.
Yes, we offer free samples for test, you are welcome to order samples to experience our excellent quality and service.
Inquiry - quotation - communication - order confirming - deposit payment - production - testing and debugging - balance payment - packing - delivery - customer receiving - after service.